HONEYWELL S87B1016 /IGNITION TRANSFORMER
APPLICATION
The S87 is a low voltage, solid state, direct spark ignition
control module for gas-fired furnaces, boilers and heating
appliances. Models are available with or without a prepurge
timer. The S87 controls the gas valve, monitors the main
burner flame and generates a high voltage for spark ignition.
FEATURES
• S87A uses a single electrode for spark ignition and flame
sensing. Use only with Resideo gas controls designed for
OSI application: V845, V854, VR845, VR854, VR8450 and
VR8540.
• S87B uses a single electrode for spark ignition and flame
sensing. Use with any gas control designed for OSI
application that is rated at 2.0 A or less. Includes optional
alarm circuit for use on system safety lockout
• S87C uses separate electrodes for spark ignition and
flame sensing. Use only with Resideo gas controls
designed for OSI application: V845, V854, VR845, VR854,
VR8450 and VR8540. For direct replacement of S825C.
See page 3.
• S87D uses separate electrodes for spark ignition and
flame sensing. Use with any gas control designed for OSI
application that is rated at 2.0 A or less. Includes optional
alarm circuit. For direct replacement of S825D. See page
3.
• S87J uses a single electrode for spark ignition and flame
sensing. Use with any gas control designed for OSI
application that is rated at 2.0 A or less. Includes a 30
second (minimum) delay for use with system prepurge.
• S87K uses separate electrodes for spark ignition and
flame sensing. Use with any gas control designed for OSI
application that is rated at 2.0 A or less. Includes a 30
second (minimum) delay for use with system prepurge.
• External, replaceable fuse protects system transÂformer
and temperature controller.
• Automatic system lockout after trial-for-ignition if
malfunction exists or main burner flame fails to ignite. All
models available with 4, 6, 11, or 21 second (nominal)
lockout time.
• Compact, solid state components for accurate, longlasting
performance.
• Convenient remote start procedure; after safety
shutdown, control module can be reset from the
temperature controller.
• Low voltage control circuit reduces wiring costs.
• Uses flame rectification principle to prove presence of
main burner flame; false flame signal resulting from short
to ground results in safety shutdown.
Electrical Ratings:
Voltage and Frequency: 25 Vac, 60 Hz.
Current Rating: 0.2 A at 25 Vac.
Valve Contacts (S87B,D,J,K): 2.0 A at 25 Vac.
Alarm Contacts (S87B,D): 0.5 A at 25 Vac.
NOTE:
Produk yang telah dikirim dapat dikembalikan atau ditukar apabila memenuhi Syarat & Ketentuan berikut:
1.barang yg dikirim beda spek dari iklan
2.barang yg dikirim beda spek dari order
3.barang yg dikirim beda merek
Produk tidak dapat dikembalikan apabila:
1.terjadi salah order oleh pembeli (salah merek / salah spek)
2.hanya karena sudah tidak membutuhkan lagi barang yg telah diorder
3.tidak mencantumkan video unboxing yang utuh (wajib tanpa potongan dan wajib tanpa editing)
4.pembeli salah pilih barang karena ketidaktahuan/coba2
5.terjadi kesalahan kirim oleh penjual tetapi pembeli merusak barang/dus produk








Ulasan
Belum ada ulasan.